| Year | Make | Model | Lot Description | Hammer Price | |
|---|---|---|---|---|---|
|
|
2015 | ANTARES VISION | AVB 106 |
2015 ANTARES VISION AVB 106 AUTOMATIC TABLET VISUAL INSPECTION MACHINES FOR TABLETS & CAPSULES S/N: 201511.8106.100 VOLTS: 480 HERTZ: 60 AMPS: 28 DESCRIPTION: TOTAL DEFECT DETECTION FOR ALL TABLETS AND CAPSULES AUTOMATIC VISUAL INSPECTION MACHINES FOR TABLETS & CAPSULES THE ANTARES VISION GROUP TABLETS AND CAPSULES INSPECTOR IS AN AUTOMATIC STANDALONE MACHINE DESIGNED TO INSPECT PHARMACEUTICAL PRODUCTS AT A HIGH THROUGHPUT UP TO 300.000 PRODUCTS/HOUR. AN EIGHT CHANNELS ROTARY DOUBLE-DRUM SYSTEM HANDLES PRODUCTS BY HOLDING THEM IN POSITION BY MEANS OF A VACUUM SYSTEM WHICH ENABLES THE IMAGES TO BE ACQUIRED ON THE ENTIRE SURFACE. DETECTION OF EVEN THE SMALLEST DEFECT OR IMPERFECTION IS GUARANTEED BY UP TO 8 COLOUR HIGH-RESOLUTION CAMERAS ACQUIRING UP TO 16 HIGH-RESOLUTION IMAGES PER PRODUCT. WIDE RANGE OF INSPECTIONS: SIZE DISCREPANCIES; SHAPE DEFECTS; DOTS; DIRT; CRACKS; COLOR DIFFERENCES; EMBOSSING; COATING IMPERFECTIONS; CHIPPED PRODUCTS; PRINTING; HOLES/DRILL; DENTS; JOINTS CONTINUITY: MECHANICAL HANDLING IS NOT SENSITIVE TO DIMENSIONAL VARIATIONS, PROVIDING CONTINUOUS AUTOMATIC INSPECTION EVEN IN CASE OF HIGHLY VARIABLE PRODUCTS EASY TO USE AND USER FRIENDLY: QUICK FORMAT CHANGEOVER, MANAGEABLE BY UP TO 5 USER LOGIN LEVELS, EASY CLEANING PROCEDURE AND MAINTENANCE EFFICIENT: PROVIDES ADVANCED STATISTICAL ANALYSES WITH VISUAL DEFECT-DETECTION FEEDBACK, AND DETAILED REJECT TYPOLOGY TO HELP IDENTIFY THE REJECT CAUSES.
|
🔒 Subscribe |
|
|
WATERS | 2695 |
WATERS 2695 SEPARATION MODULE (WATER HPLC) DESCRIPTION: THE WATERS ALLIANCE 2695 HPLC SEPARATIONS MODULE CAN BE USED FOR IN-VITRO DIAGNOSTIC TESTING TO ANALYZE MANY COMPOUNDS, INCLUDING DIAGNOSTIC INDICATORS AND THERAPEUTICALLY MONITORED COMPOUNDS. THE SEPARATIONS MODULE IS AN INTEGRATED SOLVENT AND SAMPLE MANAGEMENT PLATFORM. WATERS 2489 UV/ VISIBLE DETECTOR DESCRIPTION: THE 2489 UV/VIS DETECTOR IS THE MOST SENSITIVE AND VERSATILE DUAL-WAVELENGTH ABSORBANCE DETECTOR AVAILABLE FOR HPLC AND UHPLC. IT IS DESIGNED TO COMBINE A HIGH ENERGY DEUTERIUM SOURCE, A PRECISE OPTICAL DESIGN, AND LOW NOISE, HIGH SPEED ELECTRONICS ALL IN ONE DETECTOR. WATERS 2487 DUAL ABSORBANCE DETECTOR DESCRIPTION: THE WATERS 2487 DETECTOR FEATURES ADVANCED PROGRAMMABILITY, DUAL WAVELENGTH CAPABILITY, UNMATCHED SIGNAL-TO-NOISE PERFORMANCE, REDUCED OPTICAL BANDWIDTH AND EXCEPTIONAL LINEARITY TO PROVIDE THE HIGHEST PERFORMANCE IN UV/VIS DETECTION FOR YOUR HPLC ANALYSES. WATERS 2996 PHOTODIODE ARRAY DETECTOR DESCRIPTION: THE WATERS 2996 HPLC PHOTO DIODE ARRAY DETECTOR DELIVERS EXCEPTIONAL CHROMATOGRAPHIC AND SPECTRAL SENSITIVITY ALONGSIDE RELIABIITY. ANALYITICAL AND PREPARATIVE SEPERATIONS HAVE NEVER BEEN EASIER WITH THIS ADVANCED SPECTRAL ANALYSIS TOOL, FEATURING ENHANCED HOMOGENUITY ASSESSMENT AND COMPONENT RECOGNITION. THE WATERS 2996 OFFERS UNPRECEDENTED DETECTION AND QUANTIFICATION OF TRACE IMPURITIES. THE UNIT FEATURES START-UP DIAGNOSTICS TO ENSURE SUPERIOR PERFORMANCE PRIOR TO USE. MAXIUM CHROMAATOGRAPHIC SENSITIVITY MEANS UNPRECEDENTED TRACE IMPURITY DETECTION AND QUANTIFICATION, WHILE OPTIMIZED SPECTRAL SESNITIVITY AND PURITY ALGORITHMS ALLOW DEFINITIVE
|
🔒 Subscribe | |
|
|
VARIAN | BIO-DIS III |
VARIAN BIO-DIS III DISSOLUTION SYSTEM IS IDEAL FOR AUTOMATIC DISSOLUTION PROFILING OF EXTENDED RELEASE DOSAGE FORMS REQUIRING USP APPARATUS 3 AND EP RECIPROCATING CYLINDER SPECIFICATIONS. FEATURES INCLUDE: UP TO SIX DAYS OF RUNNING UNATTENDED, STORE UP TO 15 PROGRAMS, SIMULATE GASTROINTESTINAL CONDITIONS WITH SIMPLE PROGRAMMING, AND USE ONE INSTRUMENT TO TEST AND TRANSPORT A VARIETY OF SAMPLES.
|
🔒 Subscribe | |
|
|
KEY INTERNATIONAL | TD |
KEY INTERNATIONAL TD TABLET DE-DUSTER S/N: 0109602 DESCRIPTION: DESIGNED FOR THE OPERATOR IN MIND, THESE DE-DUSTER UNITS ARE COMPLETELY WASHED DOWN WHICH REDUCES THE DOWNTIME BETWEEN CLEANINGS. THE UNIT IS CONSTRUCTED OF MIRROR-POLISHED, STAINLESS STEEL WITH AN ADJUSTABLE BASE, VARIABLE SPEED VIBRATOR, AND AN ADJUSTABLE INLET FUNNEL, ALONG WITH WASH-DOWN MOTOR AND CONTROLS. THE UNITS ARE MADE IN THE U.S.A., ARE GENERALLY IN STOCK AND SUPPORTED BY 'OFF THE SHELF' REPLACEMENT PARTS. FEATURES: VIBRATOR AND CONTROLS ARE BUILT TO NEMA, WASH DOWN SPECIFICATIONS ALL MIRROR POLISHED STAINLESS STEEL CONTACT PARTS AS WELL AS STAINLESS STEEL EXTERIOR COVERS ADJUSTABLE TILT FEATURE, WHICH WHEN SET IN RELATION TO VIBRATION INTENSITY, DETERMINES SPEED OF TABLETS GMP DESIGNS AND CONSTRUCTION QUICK DISCONNECT CLEAR LEXAN TOP COVER STAINLESS STEEL SUPPORT COLUMN STAINLESS STEEL VACUUM NOZZLE FOR DUST CONTROL 5 LEG POLISHED ALUMINUM BASE WITH LOCKING CASTERS
|
🔒 Subscribe | |
|
|
KEY INTERNATIONAL | TD |
KEY INTERNATIONAL TABLET DEDUSTER MODEL: TD S/N: 010487 DESCRIPTION: DESIGNED FOR THE OPERATOR IN MIND, THESE DE-DUSTER UNITS ARE COMPLETELY WASHED DOWN WHICH REDUCES THE DOWNTIME BETWEEN CLEANINGS. UNIT IS CONSTRUCTED OF MIRROR POLISHED, STAINLESS STEEL WITH AN ADJUSTABLE BASE, VARIABLE SPEED VIBRATOR AND AN ADJUSTABLE INLET FUNNEL, ALONG WITH WASH DOWN MOTOR AND CONTROLS. THE UNITS ARE MADE IN THE U.S.A., ARE GENERALLY IN STOCK AND SUPPORTED BY 'OFF THE SHELF' REPLACEMENT PARTS. FEATURES: VIBRATOR AND CONTROLS ARE BUILT TO NEMA, WASH DOWN SPECIFICATIONS ALL MIRROR POLISHED STAINLESS STEEL CONTACT PARTS AS WELL AS STAINLESS STEEL EXTERIOR COVERS ADJUSTABLE TILT FEATURE, WHICH WHEN SET IN RELATION TO VIBRATION INTENSITY, DETERMINES SPEED OF TABLETS GMP DESIGNS AND CONSTRUCTION QUICK DISCONNECT CLEAR LEXAN TOP COVER STAINLESS STEEL SUPPORT COLUMN STAINLESS STEEL VACUUM NOZZLE FOR DUST CONTROL 5 LEG POLISHED ALUMINUM BASE WITH LOCKING CASTERS
|
🔒 Subscribe | |
|
|
WATERS | 2695 SEPARATIONS MODULE |
WATERS 2695 SEPARATIONS MODULE PRODUCT NUMBER: WAT270008 SERIAL NUMBER: G07SM4515A VOLTS: 100240 AMPS: 9.5. FREQUENCY: 63 HZ DESCRIPTION: THE WATERS ALLIANCE 2695 HPLC SEPARATIONS MODULE CAN BE USED FOR IN-VITRO DIAGNOSTIC TESTING TO ANALYZE MANY COMPOUNDS, INCLUDING DIAGNOSTIC INDICATORS AND THERAPEUTICALLY MONITORED COMPOUNDS. THE SEPARATIONS MODULE IS AN INTEGRATED SOLVENT AND SAMPLE MANAGEMENT PLATFORM. WATERS 2489 UV/VISIBLE DETECTOR SERIAL NUMBER: G0787E079M VOLTS: 100240 FREQUENCY: 60 VA 185 DESCRIPTION: THE 2489 UV/VIS DETECTOR IS THE MOST SENSITIVE AND VERSATILE DUAL-WAVELENGTH ABSORBANCE DETECTOR AVAILABLE FOR HPLC AND UHPLC. IT IS DESIGNED TO COMBINE A HIGH ENERGY DEUTERIUM SOURCE, A PRECISE OPTICAL DESIGN, AND LOW NOISE, HIGH SPEED ELECTRONICS ALL IN ONE DETECTOR.
|
🔒 Subscribe | |
|
|
2014 | METTLER TOLEDO | SAFELINE METAL CHECK |
2014 METTLER TOLEDO SAFELINE METAL CHECK METAL CHECK SERIAL NUMBER: 522581 VOLTAGE: 100-240 FREQUENCY: 60 HZ
|
🔒 Subscribe |
|
|
WATERS | 2695 SEPARATIONS MODULE, 2489 UV/VISIBLE DETECTOR |
WATERS 2695 SEPARATIONS MODULE PRODUCT NUMBER: WAT270886 SERIAL NUMBER: F 07SM7073A VOLTS: 100240 AMPS: 9.5. FREQUENCY: 63 WATERS 2489 UV/VISIBLE DETECTOR SERIAL NUMBER: L 0887E864R VOLTS: 100240 FREQUENCY: 60 VA 185 DESCRIPTION: THE 2489 UV/VIS DETECTOR IS THE MOST SENSITIVE AND VERSATILE DUAL-WAVELENGTH ABSORBANCE DETECTOR AVAILABLE FOR HPLC AND UHPLC. IT IS DESIGNED TO COMBINE A HIGH ENERGY DEUTERIUM SOURCE, A PRECISE OPTICAL DESIGN, AND LOW NOISE, HIGH SPEED ELECTRONICS ALL IN ONE DETECTOR.
|
🔒 Subscribe | |
|
|
WATERS | 2695 HPLC SEPARATIONS MODULE |
WATERS 2695 HPLC SEPARATIONS MODULE PRODUCT NUMBER: WAT270886 SERIAL NUMBER: F 07SM7069A VOLTS: 100240 AMPS: 9.5 FREQUENCY: 63 HZ DESCRIPTION: THE WATERS ALLIANCE 2695 HPLC SEPARATIONS MODULE CAN BE USED FOR IN-VITRO DIAGNOSTIC TESTING TO ANALYZE MANY COMPOUNDS, INCLUDING DIAGNOSTIC INDICATORS AND THERAPEUTICALLY MONITORED COMPOUNDS. THE SEPARATIONS MODULE IS AN INTEGRATED SOLVENT AND SAMPLE MANAGEMENT PLATFORM. WATERS 2489 UV/VISIBLE DETECTOR SERIAL NUMBER: B0887E698M VOLTS: 100240 FREQUENCY: 60 HZ VA 185 DESCRIPTION: THE 2489 DESCRIPTION: UV/VIS DETECTOR IS THE MOST SENSITIVE AND VERSATILE DUAL-WAVELENGTH ABSORBANCE DETECTOR AVAILABLE FOR HPLC AND UHPLC. IT IS DESIGNED TO COMBINE A HIGH ENERGY DEUTERIUM SOURCE, A PRECISE OPTICAL DESIGN, AND LOW NOISE, HIGH-SPEED ELECTRONICS ALL IN ONE DETECTOR.
|
🔒 Subscribe | |
|
|
GEORGE NUTTING CO | AV 100 |
GEORGE NUTTING CO AV 100 TABLET DEDUSTER S/N: 10413 ADJUSTABLE SLOPE AND VARIABLE INTENSITY VIBRATION OF CLEANING SCREEN. THIS ALLOWS YOU TO VARY THE SPEED OF THE TABLETS OVER THE CLEANING SCREEN. CLEANING SCREEN IS STEPPED TO TURN OVER TABLETS. COVER WITH REGULATED AND FILTERED AIR TO BLOW DUST FROM TABLETS. VACUUM NOZZLE TO REMOVE DUST. QUICK DISCONNECT COVER AND SCREEN FOR EASY CLEANING. ADJUSTABLE HEIGHT. 5 LEG BASE WITH LOCKING CASTORS. MATERIAL VALIDATION. OPTIONS: LEXAN COVER ON INFEED CHUTE. LEXAN COVER ON DISCHANRGE CHUTE.
|
🔒 Subscribe | |
|
|
KEY INTERNATIONAL | TD-101 S 03 59 |
KEY INTERNATIONAL TD-101 S 03 59 TABLET DEDUSTER: DESIGNED FOR THE OPERATOR IN MIND, THESE DEDUSTER UNITS ARE COMPLETELY WASH DOWN WHICH REDUCES THE DOWN TIME BETWEEN CLEANINGS. UNIT IS CONSTRUCTED OF MIRROR POLISHED, STAINLESS STEEL WITH AN ADJUSTABLE BASE, VARIABLE SPEED VIBRATOR AND AN ADJUSTABLE INLET FUNNEL, ALONG WITH WASH DOWN MOTOR AND CONTROLS. THE UNITS ARE MADE IN THE U.S.A., ARE GENERALLY IN STOCK AND SUPPORTED BY 'OFF THE SHELF' REPLACEMENT PARTS. FEATURES: VIBRATOR AND CONTROLS ARE BUILT TO NEMA, WASH DOWN SPECIFICATIONS ALL MIRROR POLISHED STAINLESS STEEL CONTACT PARTS AS WELL AS STAINLESS STEEL EXTERIOR COVERS ADJUSTABLE TILT FEATURE, WHICH WHEN SET IN RELATION TO VIBRATION INTENSITY, DETERMINES SPEED OF TABLETS GMP DESIGNS AND CONSTRUCTION QUICK DISCONNECT CLEAR LEXAN TOP COVER STAINLESS STEEL SUPPORT COLUMN STAINLESS STEEL VACUUM NOZZLE FOR DUST CONTROL 5 LEG POLISHED ALUMINUM BASE WITH LOCKING CASTERS
|
🔒 Subscribe | |
|
|
2019 | METTLER TOLEDO SAFELINE |
2019 METTLER TOLEDO SAFELINE METAL CHECK VOLTAGE: 110 AMPERAGE: 4A PHASE: 1 FREQUENCY: 50/60 S/N: B921693148
|
🔒 Subscribe | |
|
|
2005 | INCAP DOTT BONAPACE & C. | IN-CAP |
2005 INCAP DOTT BONAPACE & C. IN-CAP CAPSULE FILLING MACHINE S/N: 256/05 VOLT: 110 HZ: 60 BAR: 6 DESCRIPTION: 3 FULL SETS OF TOOLING CAPABLE OF PROCESSING POWDER, LIQUID, PELLETS OR CAPSULES DOSATOR AN ALTERNATIVE TO THE TAMPING POWDER SYSTEM. IT ALLOWS PROCESSING POWDERS UNSUITABLE FOR THE TAMPING PROCESS. THIS DEVICE INCREASES THE RANGE OF POWDERS WHICH THE IN-CAP MACHINE CAN PROCESS. PELLETS FEEDER IT HAS BEEN DESIGNED TO FILL PELLETS. THE CAPSULE FILLING MACHINE IS SUITABLE TO SET 3 DIFFERENT PELLETS FEEDERS ALLOWING TO PROCESS 3 DIFFERENT PRODUCTS AT THE SAME TIME. LIQUID FILLER A DEVICE DESIGNED FOR ALL LABS R&D DEPTS ETC., WHICH NEED TO FILL LIQUIDS INTO A CAPSULE. IT HAS A 2.3L HEATED HOPPER + AN ADJUSTABLE SPEED STIRRER. THE FILLING NOZZLE HAS BEEN DESIGNED TO FILL FROM 0.15 MG UP TO 1000 MG. TABLET/CAPSULE FILLER A SPECIAL DEVICE DESIGNED TO FILL TABLETS (ALSO MINI) OR CAPSULE-IN-CAPSULE (CIC). IT HAS BEEN DEVELOPED FOR SPECIAL APPLICATIONS AND IT INCREASES THE RANGE OF POSSIBLE COMBINATIONS AVAILABLE.
|
🔒 Subscribe |
|
|
WATERS | 2695 HPLC |
WATERS 2695 HPLC SEPARATIONS MODULE, FULL SPECTRUM WATER SEPARATION MODULE 2695 HPLC S/N: G07SM4552A INPUT: 100-240V AMPS: 9.5 FREQUENCY: 47-63HZ DESCRIPTION: THE WATERS ALLIANCE 2695 HPLC SEPARATIONS MODULE CAN BE USED FOR IN-VITRO DIAGNOSTIC TESTING TO ANALYZE MANY COMPOUNDS, INCLUDING DIAGNOSTIC INDICATORS AND THERAPEUTICALLY MONITORED COMPOUNDS. THE SEPARATIONS MODULE IS AN INTEGRATED SOLVENT AND SAMPLE MANAGEMENT PLATFORM. FULL SPECTRUM DUAL ABSORBANCE DETECTOR 2487 S/N: F07SMH775E UV / VISIBLE DETECTOR 2489 S/N: B0887E 640M VOLTAGE: 100-240 AMPERAGE: 15 A DESCRIPTION: THE 2489 UV/VIS DETECTOR IS THE MOST SENSITIVE AND VERSATILE DUAL- WAVELENGTH ABSORBANCE DETECTOR AVAILABLE FOR HPLC. THE DESIGN COMBINES A HIGH ENERGY DEUTERIUM SOURCE, A PRECISE OPTICAL DESIGN, AND LOW NOISE, HIGH SPEED ELECTRONICS. THESE ADVANCED CAPABILITIES TAKE UV/VIS DETECTION PERFORMANCE TO A NEW LEVEL.
|
🔒 Subscribe | |
|
|
AGILENT TECHNOLOGIES | 708 DS |
AGILENT TECHNOLOGIES 708 DS DISSOLUTION APPARATUS WITH PERISTALTIC PUMP MODEL NUMBER: 708 DS PRODUCT NUMBER: 100-2200 SERIAL NUMBER: DL1109C440 VOLTS: 115 /230 FREQUENCY: 60 HZ DESCRIPTION: AUTOMATED OR MANUAL DOSAGE DELIVERY OPTIONS, IN-VESSEL TEMPERATURE MONITORING, AND SAMPLING OPTIONS INTERCHANGEABLE DISSOLUTION ACCESSORY COMPONENTS TO MAINTAIN THE CORRECT HEIGHT TOUCH PANEL DISPLAY ENABLES EASY NAVIGATION LANGUAGE OPTIONS INCLUDE ENGLISH, SPANISH, JAPANESE, AND SIMPLIFIED CHINESE 708-DS TRUALIGN VESSELS ENSURE CORRECT VESSEL ALIGNMENT EASY PRIMING HEATER/CIRCULATOR SITS BEHIND WATER BATH TO SAVE VALUABLE BENCH SPACE WITH MINIMAL VIBRATION DECREASE CLEANING TIME WITH THE ANGLED WATER BATHMAKES CLEANING EASY AND EFFICIENT INTEGRATE WITH AGILENT DISSOLUTION WORKSTATION SOFTWARE FOR AUTOMATED CONTROL OF UP TO FOUR SYSTEMS FROM ONE PC ONLINE ANALYSIS VIA THE AGILENT CARY 60 UV-VIS SPECTROPHOTOMETER AND AGILENT CARY WINUV DISSOLUTION SOFTWARE
|
🔒 Subscribe | |
|
|
AGILENT TECHNOLOGIES | 708DS |
AGILENT TECHNOLOGIES 708DS DISSOLUTION APPARATUS WITH PERISTALTIC PUMP. MODEL NUMBER: 708DS PRODUCT NUMBER: 100-2200 SERIAL NUMBER: DL1103C300 VOLTS: 115 /230 FREQUENCY: 60 HZ DESCRIPTION: AUTOMATED OR MANUAL DOSAGE DELIVERY OPTIONS, IN-VESSEL TEMPERATURE MONITORING, AND SAMPLING OPTIONS INTERCHANGEABLE DISSOLUTION ACCESSORY COMPONENTS TO MAINTAIN THE CORRECT HEIGHT TOUCH PANEL DISPLAY ENABLES EASY NAVIGATION LANGUAGE OPTIONS INCLUDE ENGLISH, SPANISH, JAPANESE, AND SIMPLIFIED CHINESE 708-DS TRUALIGN VESSELS ENSURE CORRECT VESSEL ALIGNMENT EASY PRIMING HEATER/CIRCULATOR SITS BEHIND WATER BATH TO SAVE VALUABLE BENCH SPACE WITH MINIMAL VIBRATION DECREASE CLEANING TIME WITH THE ANGLED WATER BATH MAKES CLEANING EASY AND EFFICIENT INTEGRATE WITH AGILENT DISSOLUTION WORKSTATION SOFTWARE FOR AUTOMATED CONTROL OF UP TO FOUR SYSTEMS FROM ONE PC ONLINE ANALYSIS VIA THE AGILENT CARY 60 UV-VIS SPECTROPHOTOMETER AND AGILENT CARY WINUV DISSOLUTION SOFTWARE
|
🔒 Subscribe | |
|
|
2019 | AGILENT | CARY 60 UV-VISION |
2019 AGILENT CARY 60 UV-VISION CARY 60 UV-VIS SYSTEM VERSATILITY MAKES IT IDEAL FOR MANY APPLICATIONS, AND THE WIDE RANGE OF ACCESSORIES EXTEND THE CARY 60 CAPABILITIES TO MEASURE A DIVERSE RANGE OF SAMPLE TYPES ACCURATELY, RELIABLY, AND EASILY. RAPID AND REMOTE MEASUREMENTS USING FIBER OPTIC PROBES ELIMINATE THE NEED FOR CUVETTES, REDUCING SAMPLE LOSS AND USER ERROR, AND INCREASING PRODUCTIVITY. THE 18-CELL CHANGER ALLOWS FOR AUTOMATED HIGH-THROUGHPUT ANALYSIS OF LIQUIDS, INCLUDING COLOR OR CONCENTRATION MEASUREMENTS. S/N: MY19180016 PN: G6860A
|
🔒 Subscribe |
|
|
VARIAN | VK7000 |
VARIAN VK7000 DISSOLUTION APPARATUS, S/N: 1-0951-1107. VOLTAGE: 115; FREQUENCY: 60HZ; AMPERAGE: 3. DESCRIPTION: THE VARIAN VK7000 DISSOLUTION APPARATUS IS AN AUTOMATION-FRIENDLY INSTRUMENT WITH AN EASY-TO-USE DESIGN AND OFFERS DIRECT ACCESS FOR EASY CLEANING, EXCELLENT VISIBILITY AND ADVANCED TEMPERATURE CONTROL. PERIL-STATIC PUMP, MODEL: VK810, S/N: 17-2692-0905, VOLTAGE: 115; FREQUENCY: 60HZ; AMPERAGE: 1A. VARIAN VK8000, S/N: 25-0907-1107, VOLTAGE: 115; FREQUENCY: 60HZ; AMPS: 2. DESCRIPTION: THE VK 8000 AND ITS ACCESSORIES HAVE BEEN CAREFULLY DESIGNED SO THAT WHEN USED PROPERLY YOU HAVE AN ACCURATE, FAST, FLEXIBLE, AND SAFE INSTRUMENT. IF THE EQUIPMENT IS USED IN A MANNER NOT SPECIFIED BY THE MANUFACTURER, THE PROTECTION PROVIDED BY THE EQUIPMENT MAY BE IMPAIRED. OPERATION OF A VK 8000 AND ACCESSORIES INVOLVES THE USE OF AQUEOUS LIQUIDS. UNSKILLED, IMPROPER, OR CARELESS USE OF THIS INSTRUMENT CAN CREATE SHOCK HAZARDS, FIRE HAZARDS, OR OTHER HAZARDS WHICH CAN CAUSE DEATH, SERIOUS INJURY TO PERSONNEL, OR SEVERE DAMAGE TO EQUIPMENT AND PROPERTY. VARIAN VK750D, S/N: 6-0952-1107, VOLTAGE: 115V; FREQUENCY: 60HZ; AMPS: .15 AMPS. DESCRIPTION: THE VK 750D HAS BEEN CAREFULLY DESIGNED SO THAT WHEN USED PROPERLY YOU HAVE AN ACCURATE, FAST, FLEXIBLE, AND SAFE INSTRUMENT. IF THE EQUIPMENT IS USED IN A MANNER NOT SPECIFIED BY THE MANUFACTURER, THE PROTECTION PROVIDED BY THE EQUIPMENT MAY BE IMPAIRED. OPERATION OF A VK 750D INVOLVES THE USE OF AQUEOUS LIQUIDS. UNSKILLED, IMPROPER, OR CARELESS USE OF THIS INSTRUMENT CAN CREATE SHOCK HAZARDS, FIRE HAZARDS, OR OTHER HAZARDS WHICH CAN CAUSE DEATH, SERIOUS INJURY TO PERSONNEL, OR SEVERE DAMAGE TO EQUIPMENT AND PROPERTY.
|
🔒 Subscribe | |
|
|
AGILENT TECHNOLOGIES | G7910 G7911A |
AGILENT TECHNOLOGIES G7910 G7911A DISSOLUTION APPARATUS S/N: DL1103C309 VOLTS: 115 /230 FREQUENCY: 60 HZ DESCRIPTION: AUTOMATED OR MANUAL DOSAGE DELIVERY OPTIONS, IN-VESSEL TEMPERATURE MONITORING, AND SAMPLING OPTIONS INTERCHANGEABLE DISSOLUTION ACCESSORY COMPONENTS TO MAINTAIN THE CORRECT HEIGHT TOUCH PANEL DISPLAY ENABLES EASY NAVIGATION LANGUAGE OPTIONS INCLUDE ENGLISH, SPANISH, JAPANESE, AND SIMPLIFIED CHINESE 708-DS TRUALIGN VESSELS ENSURE CORRECT VESSEL ALIGNMENT EASY PRIMING HEATER/CIRCULATOR SITS BEHIND WATER BATH TO SAVE VALUABLE BENCH SPACE WITH MINIMAL VIBRATION DECREASE CLEANING TIME WITH THE ANGLED WATER BATHMAKES CLEANING EASY AND EFFICIENT INTEGRATE WITH AGILENT DISSOLUTION WORKSTATION SOFTWARE FOR AUTOMATED CONTROL OF UP TO FOUR SYSTEMS FROM ONE PC ONLINE ANALYSIS VIA THE AGILENT CARY 60 UV-VIS SPECTROPHOTOMETER AND AGILENT CARY WINUV DISSOLUTION SOFTWARE 8000 DISSOLUTION SAMPLING STATION MODEL NUMBER: VK8000 PRODUCT NUMBER: 15363 SERIAL NUMBER: DL1103C210 VOLTS: 115 DESCRIPTION: THE 8000 DISSOLUTION SAMPLING STATION PROVIDES AN UNATTENDED SOLUTION FOR AUTOMATED SAMPLING FROM A DISSOLUTION APPARATUS. THE INSTRUMENT MAY BE CONFIGURED TO CONTROL ANY INSTRUMENT SETUP WITH A USP APPARATUS 1 (BASKETS), 2 (PADDLES), 3 (RECIPROCATING CYLINDER), 5 (PADDLE OVER DISK), 6 (ROTATING CYLINDER), OR 7 (RECIPROCATING HOLDER) OFFERED BY AGILENT TECHNOLOGIES, INC. THE FIRMWARE CAN STORE UP TO 15 DIFFERENT SAMPLING PROGRAMS. DISSOLUTION APPARATUS PARAMETERS ARE ENTERED AS PART OF THE 8000 PROGRAM. THESE PARAMETERS ARE DOWNLOADED TO THE DISSOLUTION APPARATUS WHEN BEGINNING A TEST WITH THE 8000.
|
🔒 Subscribe | |
|
|
2014 | METTLER TOLEDO SAFELINE | METAL CHECK |
2014 METTLER TOLEDO SAFELINE METAL CHECK SERIAL NUMBER: C114493105 MODEL TO AL VOLTAGE: 100240 AMPERAGE: 3A FREQUENCY: 60 HZ
|
🔒 Subscribe |
|
|
AGILENT TECHNOLOGIES | G7910 G7911A |
AGILENT TECHNOLOGIES G7910 G7911A 708-DS DISSOLUTION APPARATUS S/N: DL1103C306. PRODUCT NUMBER: G7 9106402. VOLTS: 115 /230. FREQUENCY: 60 HZ. DESCRIPTION: AUTOMATED OR MANUAL DOSAGE DELIVERY OPTIONS, IN-VESSEL TEMPERATURE MONITORING, AND SAMPLING OPTIONS. INTERCHANGEABLE DISSOLUTION ACCESSORY COMPONENTS TO MAINTAIN THE CORRECT HEIGHT. TOUCH PANEL DISPLAY ENABLES EASY NAVIGATION. LANGUAGE OPTIONS INCLUDE ENGLISH, SPANISH, JAPANESE, AND SIMPLIFIED CHINESE. 708-DS TRUALIGN VESSELS ENSURE CORRECT VESSEL ALIGNMENT. EASY PRIMING HEATER/CIRCULATOR SITS BEHIND WATER BATH TO SAVE VALUABLE BENCH SPACE WITH MINIMAL VIBRATION. DECREASE CLEANING TIME WITH THE ANGLED WATER BATH MAKES CLEANING EASY AND EFFICIENT. INTEGRATE WITH AGILENT DISSOLUTION WORKSTATION SOFTWARE FOR AUTOMATED CONTROL OF UP TO FOUR SYSTEMS FROM ONE PC. ONLINE ANALYSIS VIA THE AGILENT CARY 60 UV-VIS SPECTROPHOTOMETER AND AGILENT CARY WINUV DISSOLUTION SOFTWARE. 8000 DISSOLUTION SAMPLING STATION. MODEL NUMBER: VK8000. PRODUCT NUMBER: 15363. SERIAL NUMBER: DL1109C521. VOLTS: 115. DESCRIPTION: THE 8000 DISSOLUTION SAMPLING STATION PROVIDES AN UNATTENDED SOLUTION FOR AUTOMATED SAMPLING FROM A DISSOLUTION APPARATUS. THE INSTRUMENT MAY BE CONFIGURED TO CONTROL ANY INSTRUMENT SETUP WITH A USP APPARATUS.
|
🔒 Subscribe | |
|
|
BUDZAR | LTW 22.5 SP |
BUDZAR LTW 22.5 SP PROCESS CHILLER VOLTS: 160 PHASE: 3 FREQUENCY: 60 HZ FULL LOAD AMPERAGE: 36.97 MAX FUSE SIZE: 50A MCA FOR 1.5 A. DESCRIPTION: LARGEST MOTOR 15 HP ENCLOSURE TYPE NEMA1 COOLING CAPACITY 1.95 TR -100 FAHRENHEIT. PUMP RATING, 12/2 TO GMT AT 164/59TDH PROCESS FLUID SYLTHERM XLT S/N: 20160729274
|
🔒 Subscribe | |
|
|
LOGAN INSTRUMENTS CORP | 100 HTP |
LOGAN INSTRUMENTS CORP 100 HTP AUTOMATIC VESSEL CLEANER. 12/14 VOLTS; 110 AMPERAGE; 10 HZ; 60. S/N: 1121964034. DESCRIPTION: UTILIZE THIS MACHINE BY MANUALLY CLEANING DISSOLUTION VESSELS AND AUTOMATE AND VALIDATE THE CLEANING OF DISSOLUTION VESSELS
|
🔒 Subscribe | |
|
|
WATERS | 2695 HPLC |
WATERS 2695 HPLC SEPARATIONS MODULE S/N: G07SM4539A INPUT: 100-240V AMPS: 9.5 FREQUENCY: 47-63HZ DESCRIPTION: THE WATERS ALLIANCE 2695 HPLC SEPARATIONS MODULE CAN BE USED FOR IN-VITRO DIAGNOSTIC TESTING TO ANALYZE MANY COMPOUNDS, INCLUDING DIAGNOSTIC INDICATORS AND THERAPEUTICALLY MONITORED COMPOUNDS. THE SEPARATIONS MODULE IS AN INTEGRATED SOLVENT AND SAMPLE MANAGEMENT PLATFORM. WATERS 2487 DUAL ABSORBANCE DETECTOR S/N: G0787E VOLTAGE: 100-240 AMPS: 3.5 FREQUENCY: 50-60HZ DESCRIPTION: YOU CAN USE THE WATERS 2487 DUAL ABSORBANCE DETECTOR FOR IN-VITRO DIAGNOSTIC TESTING TO ANALYZE MANY COMPOUNDS, INCLUDING DIAGNOSTIC INDICATORS AND THERAPEUTICALLY MONITORED COMPOUNDS.
|
🔒 Subscribe | |
|
|
WATERS | 2695 HPLC |
WATERS 2695 HPLC SEPARATIONS MODULE. INPUT: 100-240V AMPS: 9.5 FREQUENCY: 47-63HZ DESCRIPTION: THE WATERS ALLIANCE 2695 HPLC SEPARATIONS MODULE CAN BE USED FOR IN-VITRO DIAGNOSTIC TESTING TO ANALYZE MANY COMPOUNDS, INCLUDING DIAGNOSTIC INDICATORS AND THERAPEUTICALLY MONITORED COMPOUNDS. THE SEPARATIONS MODULE IS AN INTEGRATED SOLVENT AND SAMPLE MANAGEMENT PLATFORM. FULL SPECTRUM DUAL ABSORBANCE DETECTOR 2487 SN: K04487 VOLTAGE: 100-240 AMPS: 3.5 FREQUENCY: 50-60 DESCRIPTION: YOU CAN USE THE WATERS 2487 DUAL ABSORBANCE DETECTOR FOR IN-VITRO DIAGNOSTIC TESTING TO ANALYZE MANY COMPOUNDS, INCLUDING DIAGNOSTIC INDICATORS AND THERAPEUTICALLY MONITORED COMPOUNDS.
|
🔒 Subscribe | |
|
|
AGILENT TECHNOLOGIES | 7697A |
AGILENT TECHNOLOGIES 7697A HEADSPACE SAMPLER 12-VIAL CAPACITY CONFIGURATION IS PERFECT FOR ACADEMIC LABS AND THOSE WITH SMALL SAMPLE LOADS STANDARD 111 SAMPLE CONFIGURATION WITH THREE PRIORITY SAMPLES TRAYS CAN BE EXCHANGED DURING A SEQUENCE FOR INCREASED SAMPLE CAPACITY HYDROGEN CARRIER AND AUTO SLEEP/WAKE MODES CONSERVE VALUABLE LABORATORY RESOURCES CONTROL THROUGH AGILENT OPENLAB CDS SOFTWARE AND AGILENT MASSHUNTER SOFTWARE OTHER SOFTWARE CONTROL WITH WATERS EMPOWERTM 2 AND WATERS EMPOWERTM 3 SOFTWARE INDEPENDENT CONTROL OF VIAL PRESSURIZATION AND COLUMN HEAD PRESSURE PROVIDES INCREASED PRECISION BY ENSURING NO BACK PRESSURE DURING SAMPLE TRANSFER AUTOMATIC VIAL LEAK TEST CHECKS EACH VIAL DURING PRESSURIZATION - WITHOUT TIME-CONSUMING CALIBRATION - TO ENSURE THAT EVERY SAMPLE IS PROPERLY CAPPED SAMPLE BAR CODE READER WITH DATA TRANSFER CAPABILITIES ALLOWS YOU TO TRACK SAMPLES BEFORE THEY ENTER THE OVEN MULTIPLE HEADSPACE CONCENTRATIONS (MHC) WITH UP TO 100 EXTRACTIONS PER GC START ALLOWS FOR MORE COMPLETE SAMPLING AND INCREASED SENSITIVITY MULTIPLE HEADSPACE EXTRACTIONS (MHE) WITH UP TO 100 EXTRACTIONS PER VIAL SUPPORTS 10-ML, 20-ML, OR 22-ML VIALS WITHOUT AN ADAPTER METHOD DEVELOPMENT SOFTWARE TRANSFERS METHODS FROM ANY HEADSPACE SYSTEM OR QUICKLY DESIGNS A METHOD FROM SCRATCH USING JUST A FEW KNOWN PARAMETERS SAMPLES DEPRESSURIZE BEFORE RETURNING TO THE TRAY TRANSFER LINE INTERFACE ACCESSORY ALLOWS A HEADSPACE SAMPLER AND ALS TO CONNECT TO THE SAME INLET ON THE GC S/N:13180001 VOLTS: 120 (PSIG): 120
|
🔒 Subscribe | |
|
|
1998 | BOSCH | KKE1500 |
1998 BOSCH KKE1500 TABLET INSPECTION SYSTEM S/N: 782622 VOLTAGE: 250 AMPERAGE: 30 TOOLING SETS INCLUDED SIZE 0 SIZE 00 SIZE 000 TWO SETS OF SIZE 2 TOOLING SIZE 3 SIZE AA SIZE B DESCRIPTION: BOSCH MODEL KKE1500 WITH BOB CAPSULE CHECKWEIGHER. CAPABLE OF HANDLING HARD GELATIN CAPSULES IN SIZES FROM 00, 0, 1-4 SIZE RANGES.
|
🔒 Subscribe |
|
|
2012 | RIVA | MINI PRESS MII |
2012 RIVA MINI PRESS MII TABLET PRESS VOLTAGE: 220V PHASE: 1 THIS ECCENTRIC TABLE SINGLE-PUNCH TABLET PRESS IS THE SMALLEST PRESS IN OUR MACHINE FAMILY. DEVELOPED FOR PRODUCTION OF SMALL BATCHES AND GALENIC RESEARCH AND DEVELOPMENT. IT FEATURES A DOSAGE ADJUSTMENT SYSTEM FOR TABLET WEIGHT CONTROL, A SPEED DRIVE, AND, OPTIONALLY, A TABLET HARDNESS CONTROL SYSTEM DURING THE COMPRESSION STAGE. THE GEARBOX IS ASSEMBLED ON A CABINET SEPARATED FROM THE COMPRESSION ZONE. WE MUST MENTION ITS QUICK AND VERSATILE TOOLING CHANGE MECHANISM WHICH IS FULLY DESIGNED UNDER GMP STANDARDS WITH AISI 316 STAINLESS STEEL MACHINED SURFACES, FORMING A SOLID, PRECISE AND RELIABLE MACHINE.
|
🔒 Subscribe |
|
|
LABCONCO | 3946631 |
LABCONCO 3946631 FUME HOOD VOLTAGE: 115 PHASE: 1 FREQUENCY: 60 HZ AMPS: 3 DESCRIPTION: XPERT FILTERED BALANCE STATIONS ARE VENTED ENCLOSURES THAT PROTECT PEOPLE DURING POWDER WEIGHING OPERATIONS. THEY HAVE A BUILT-IN HEPA FILTER THAT REMOVES PARTICULATES SO THAT AND EXHAUSTS CLEAN AIR IS EXHAUSTED FROM THE STATION. S/N: 070976409C
|
🔒 Subscribe | |
|
|
VARIAN | VK 7000 |
VARIAN VK 7000 DISSOLUTION APPARATUS S/N: 1-0946-1107 VOLTAGE: 115V AMPS: 3 DESCRIPTION: THE VARIAN VK7000 DISSOLUTION APPARATUS IS AN AUTOMATION-FRIENDLY INSTRUMENT WITH AN EASY-TO-USE DESIGN AND OFFERS DIRECT ACCESS FOR EASY CLEANING, EXCELLENT VISIBILITY AND ADVANCED TEMPERATURE CONTROL. VARIAN VK 750D DIGITAL MANUAL: MODEL: M65-3000 SN: 6-2775-0898 VOLTAGE: 115V FREQUENCY: 60 HZ AMPS: 10A DESCRIPTION: THE VK 750D HAS BEEN CAREFULLY DESIGNED SO THAT WHEN USED PROPERLY YOU HAVE AN ACCURATE, FAST, FLEXIBLE, AND SAFE INSTRUMENT. IF THE EQUIPMENT IS USED IN A MANNER NOT SPECIFIED BY THE MANUFACTURER, THE PROTECTION PROVIDED BY THE EQUIPMENT MAY BE IMPAIRED. OPERATION OF A VK 750D INVOLVES THE USE OF AQUEOUS LIQUIDS. UNSKILLED, IMPROPER, OR CARELESS USE OF THIS INSTRUMENT CAN CREATE SHOCK HAZARDS, FIRE HAZARDS, OR OTHER HAZARDS WHICH CAN CAUSE DEATH, SERIOUS INJURY TO PERSONNEL, OR SEVERE DAMAGE TO EQUIPMENT AND PROPERTY. VARIAN VK8000 DIGITAL MANUAL: DESCRIPTION: THE VK 8000 AND ACCESSORIES HAVE BEEN CAREFULLY DESIGNED SO THAT WHEN USED PROPERLY YOU HAVE AN ACCURATE, FAST, FLEXIBLE, AND SAFE INSTRUMENT. IF THE EQUIPMENT IS USED IN A MANNER NOT SPECIFIED BY THE MANUFACTURER, THE PROTECTION PROVIDED BY THE EQUIPMENT MAY BE IMPAIRED. OPERATION OF A VK 8000 AND ACCESSORIES INVOLVES THE USE OF AQUEOUS LIQUIDS. UNSKILLED, IMPROPER, OR CARELESS USE OF THIS INSTRUMENT CAN CREATE SHOCK HAZARDS, FIRE HAZARDS, OR OTHER HAZARDS WHICH CAN CAUSE DEATH, SERIOUS INJURY TO PERSONNEL, OR SEVERE DAMAGE TO EQUIPMENT AND PROPERTY. SN: 25-0906-1107 VOLTAGE: 115V FREQUENCY: 60HZ AMPS: 2A VARIAN 810 (PERISTALTIC PUMP) DESCRIPTION: THE AGILENT 810 IS A FLEXIBLE, BI-DIRECTIONAL PERISTALTIC PUMP WITH 16-CHANNEL MAXIMUM CAPACITY FOR SAMPLE TRANSFER IN ALL DISSOLUTION SAMPLING SYSTEMS, AND AN 8-ROLLER DESIGN FOR SMOOTH FLOW. SN: 17-2801-0206 VOLTAGE: 115V FREQUNECY: 60HZ AMPS: 10A
|
🔒 Subscribe | |
|
|
MARBLE TABLETOPS L22 X W36 MARBLE TABLE WITH TABLE TOP L22 X W36 X H29
|
🔒 Subscribe | |||
|
|
4 LIFT LINKS 3000 AND MARBLE TABLE L22 X W36 X H29
|
🔒 Subscribe | |||
|
|
DAYTON | 1YNW8A |
DAYTON 1YNW8A SHOP FAN 42 120VAC // 60 HZ // 7A
|
🔒 Subscribe | |
|
|
SARTORIUS | CAISL3-U |
FLOOR SCALE PLATFORM SARTORIUS CAISL3-U FLOOR SCALE PLATFORM WITHOUT INDICATORS. DESCRIPTION: USED TO WEIGH BULKY ITEMS SUCH AS CONTAINERS OR PALLETS, OR TO COUNT A VERY HIGH AMOUNT OF SMALLER PIECES SUCH AS SCREWS, BOLTS OR MECHANISED PARTS.
|
🔒 Subscribe | |
|
|
SARTORIUS | CAISL3-U |
SARTORIUS CAISL3-U FLOOR SCALE PLATFORM USED TO WEIGH BULKY ITEMS SUCH AS CONTAINERS OR PALLETS, OR TO COUNT A VERY HIGH AMOUNT OF SMALLER PIECES SUCH AS SCREWS, BOLTS OR MECHANISED PARTS.
|
🔒 Subscribe | |
|
|
ISOTEMP |
ISOTEMP LABORATORY REFRIGERATOR CATALOGUE NUMBER: 139 862 45GR VOLTS: 115 HERTZ: 60 AMPS: 10.5. S/N: 306-9003 DESCRIPTION: DUAL DOOR FRIDGE, FEATURES EASY TO USE LCD SCREEN.
|
🔒 Subscribe | ||
|
|
2000 | FELDMEIER | 600 L |
2000 FELDMEIER 600 L JACKETED TANK S/N: 18S 0731 DESCRIPTION: OUTERSHELL 316 L STAINLESS STEEL NATIONAL BOARD CERTIFICATION, 5904 VESSEL, MAWP 60 PSI AT 300 FAHRENHEIT
|
🔒 Subscribe |
|
|
FISHER SCIENTIFIC | 725G |
FISHER SCIENTIFIC 725G TEMP OVEN VOLTS: 120 AMPS: 11 FREQUENCY: 60 HZ DESCRIPTION: CONSISTENT, RELIABLE RESULTS OUTSTANDING TEMPERATURE UNIFORMITY AND STABILITY TO KEEP SAMPLES AT DESIRED CONDITION WIDE TEMPERATURE RANGE: 50 TO 250C INTUITIVE AND EASYTOUSE MICROPROCESSOR CONTROLLER LARGE, EASYTOREAD FLUORESCENT DISPLAY AUTOMATIC OVER TEMPERATURE ALARM ON/OFF TIMER FOR AUTOMATED OPERATION EASY CALIBRATION ROUTINE ENSURES TEMPERATURE COMPLIANCE OVER TIME CORROSION RESISTANT STAINLESS STEEL INTERIOR (1.4016 / AISI 430) WITH SMOOTH CORNERS FOR EASY CLEANING MANUAL CONTROLLED FRESH AIR DAMPER TO ADJUST AIR EXCHANGE DOORS CAN OPEN TO OVER 180 DEGREES FOR OPTIMAL ACCESS FLEXIBLE SHELVING SYSTEM WITH DIFFERENT POSITIONS TO OPTIMIZE CHAMBER SPACE OUTSTANDING FOOTPRINT/VOLUME RATIO REDUCES REQUIRED BENCH SPACE STACKABLE SAMESIZEUNITS, WITH OPTIONAL HEAT SHIELD, WITHOUT THE NEED FOR TOOLS STAINLESS STEEL EXTERIOR PROVIDES A CLEAN, PROFESSIONAL LOOK FOR YOUR LAB AND THE SURFACE IS STRUCTURED TO AVOID SHOWING FINGERPRINTS APPLICATIONS: SAMPLE DRYING, BAKING, AGING TESTS, GLASSWARE DRYING, DRY STERILIZATION, PROCESSING ELECTRONICS S/N: 410 AND 0041
|
🔒 Subscribe | |
|
|
TWO GRANITE TABLES DIMENSIONS: L35 X W24 X H29
|
🔒 Subscribe | |||
|
|
FAN TECH | 150LGR |
FAN TECH 150LGR DEHUMIDIFIER: LOW GRAIN REFRIGERANT SYSTEM REMOVES MORE MOISTURE FROM THE AIR THAN STANDARD REFRIGERANT SYSTEMS. LOW TEMPERATURE OPERATION TO 40F ALLOWS MOISTURE TO BE REMOVED FROM THE AIR AT LOWER HUMIDITY LEVELS THAN STANDARD. TOUGH ROTOMOLDED CABINET WITHSTANDS THE RIGORS OF OPERATION, JOB TO JOB, SITE TO SITE. ELECTRONIC CONTROLS FOR PRECISE, CONVENIENT SETUP AND SIMPLE OPERATION. STREAMLINED PROFILE WITH NO KNOBS OR BUTTONS THAT CAN BE DAMAGED. DIGITAL HOUR METER FOR RECORDING JOB TIMES EVEN WHEN THE UNIT IS UNPLUGGED. 300 CFM BLOWER TO EFFICIENTLY MOVE MORE HUMID AIR THROUGH THE SYSTEM. INTEGRATED HANDLES (UPPER/LOWER) ALLOW FOR EASY LIFTING JOB TO JOB AND NO PARTS TO GET DAMAGED. TWIN 5 INCH REAR VENTS ALLOW THE WARM DRY AIR TO BE VENTED OUT OR USED TO AID IN DRYING THE AREA.
|
🔒 Subscribe | |
|
|
THERMO SCIENTIFIC | 2866 |
THERMO SCIENTIFIC 2866 WATER BATH. MICROPROCESSOR CONTROL WITH DIGITAL LED DISPLAY. SET TEMPERATURE IN 0.1C INCREMENTS. IDEAL FOR APPLICATIONS WHERE TEMPERATURE UNIFORMITY AND CONTROL ARE CRITICAL, SUCH AS ENZYMES AND SEROLOGY. ELEVATED SAMPLE PLATFORM FOR MORE THOROUGH CIRCULATION. ONE YEAR PARTS AND LABOR WARRANTY. FREQUENCY: 60 HZ. PHASE: 1. S/N: 19405292
|
🔒 Subscribe | |
|
|
VWR SCIENTIFIC | 750T |
VWR SCIENTIFIC AQUA SONIC WATER BATH MODEL: 750T ULTRASONIC BATHS CREATE ULTRASONIC WAVES IN THE TANKED WATER TO AGGRESSIVELY CLEAN GLASSWARE AND INSTRUMENTS FROM GRIME. ULTRASONIC CLEANING USING HIGH FREQUENCY SOUND WAVES IS HIGHLY EFFECTIVE AND EFFICIENT. THE STEEL CHAMBER IS RESISTANT TO CAVITATION BUBBLES AND STRONG SOLVENTS WHEN ENHANCED CLEANING IS REQUIRED. CAPABLE OF ADJUSTING THE POWER EXERTED, THE COMPACT ULTRASONIC BATHS PROTECT FRAGILE EQUIPMENT COMMON IN ANALYTICAL OR MEDICAL LABORATORIES. FULL CLEANSING CYCLES TAKE ONLY MINUTES TO COMPLETE AND WILL AUTOMATICALLY SHUT OFF WHEN TIMED SETTING IS REACHED. S/N: 21811-832 VOLTS: 117 FREQUENCY: 60
|
🔒 Subscribe | |
|
|
THERMO SCIENTIFIC | POLY 15 CIMAREC I MULTIPOINT |
LOT OF 9 THERMO SCIENTIFIC POLY 15 CIMAREC I MULTIPOINT (MULTI-POSITION STIRRER) DESCRIPTION: RUGGED, POWDER-COATED, STAINLESS-STEEL HOUSING STIR SPEEDS UP TO 990RPM SUITABLE FOR 15 250ML BEAKERS OR 6 1L FLASKS IP32 PROTECTION RATED VAROMAG ELECTRONICRUHRER POLY 15 (MULTI-POSITION STIRRER) DESCRIPTION: MULTI-POSITION STIRRERS WITH DIRECT CONTROL FOR UP TO 15 VESSELS, ARE IDEAL FOR GENERAL LABORATORY AND MASS SCREENING APPLICATIONS. UNITS PROVIDE SMOOTH STIRRING EVEN AT LOW SPEEDS AND ARE SUITABLE FOR USE WITH 15250 ML BEAKERS OR 61 LITRE FLASKS. -ROBUST AND COMPACT CONSTRUCTION WITH POWDER COATED STEEL HOUSING -MAINTENANCE AND WEAR FREE MOTOR -EASY TO USE MICROPROCESSOR CONTROL -FULLY SYNCHRONIZED SPEEDS FOR 100% COMPARABILITY OF SAMPLES -CAN BE USED AT -10 TO +40 C (95% RELATIVE HUMIDITY)
|
🔒 Subscribe | |
|
|
THERMO SCIENTIFIC | 2849 |
THERMO SCIENTIFIC 2849 WATERBATH S/N: 230585541 FREQUENCY: 60 HZ PHASE: 1 DESCRIPTION: THIS NON-HAZARDOUS GLASS THERMOMETER READS IN 1.0C INCREMENTS. IT IS 305MM (12IN) LONG AND READ FROM 0 TO 100C.
|
🔒 Subscribe | |
|
|
BENCHTOP SOLDERING-FUME EXTRACTOR HAVE TWO ARTICULATING ARMS TO REMOVE FUMES FROM TWO WORKSTATIONS. THE ARTICULATING ARMS CAN BE POSITIONED INDIVIDUALLY AROUND ONE OR TWO WORKPIECES. EXTRACTORS FILTER CONTAMINATED AIR AND RETURN CLEAN AIR TO THE WORKSPACE, ELIMINATING THE NEED FOR VENTING TO AN OUTSIDE SPACE.
|
🔒 Subscribe | |||
|
|
VWR | 1400E |
VWR 1400E OVEN VOLTS: 115 FREQUENCY: 60 HZ AMPS: 4 DIGITAL MANUAL: DESCRIPTION: THIS UNIT IS AN ECONOMY VACUUM OVEN FOR PROFESSIONAL, INDUSTRIAL OR EDUCATIONAL USE WHERE THE PREPARATION OR TESTING OF MATERIALS IS DONE AT APPROXIMATELY ATMOSPHERIC PRESSURE AND NO FLAMMABLE, VOLATILE OR COMBUSTIBLE MATERIALS ARE BEING HEATED. THIS UNIT IS NOT INTENDED FOR HAZARDOUS OR HOUSEHOLD LOCATIONS OR USE. S/N: 0901802
|
🔒 Subscribe | |
|
|
PANASONIC | MCO-170M |
PANASONIC MCO-170M INCUBATOR EXTERNAL DIMENSIONS (W X D X H) 620 X 730 X 905 MM INTERNAL DIMENSIONS (W X D X H) 490 X 523 X 665 MM VOLUME: 161 LITERS TEMPERATURE CONTROL RANGE & FLUCTUATION AT +5 ~ +50, 0.1 C TEMPERATURE UNIFORMITY: 0.25 C CO2 CONTROL RANGE & FLUCTUATION: 0 ~ 20, 0.15 % O2 CONTROL RANGE & FLUCTUATION: 1 -18 AND 22 - 80, 0.2 % HUMIDITY LEVEL & FLUCTUATION: 95, 5 %RH STERILIZATION METHOD: H2O2 DECONTAMINATION TEMPERATURE SENSOR: THERMISTOR CO2 SENSOR: DUAL IR O2 SENSOR: STABILIZED ZIRCONIA SENSOR DISPLAY TOUCH PANEL (WVGA FULL COLOR LCD) AND USB DATA LOGGING DESCRIPTION: THE INCUSAFE MCO-170M MULTIGAS INCUBATOR OFFERS THE MOST PRECISE REGULATION OF OXYGEN AND OTHER GASES, WHILE MAINTAINING SUPERIOR TEMPERATURE UNIFORMITY, CONTAMINATION CONTROL, AND USABILITY. CULTURING CELLS AT PHYSIOLOGICAL OXYGEN LEVELS ALLOWS THEM TO GROW FASTER, LIVE LONGER, AND EXPERIENCE FEWER MUTATIONS. THE INCUSAFE MCO-170M MULTIGAS INCUBATOR HELPS TO ACHIEVE MORE ACCURATE RESULTS WHEN CULTURING CELLS AT PHYSIOLOGICAL OXYGEN LEVELS AND IS THEREFORE IDEALLY SUITED FOR MAMMALIAN TISSUE RESEARCH APPLICATIONS, CELLULAR THERAPY, STEM CELL RESEARCH, PATHOPHYSIOLOGICAL STUDIES AND PHARMACEUTICAL PRODUCTION PROCESSES. IDEALLY SUITED FOR: STEM CELL RESEARCH & DIFFERENTIATION IN VITRO FERTILIZATION REGENERATIVE MEDICINE PRIMARY CELL CULTURING CANCER RESEARCH EMBRYO STUDIES S/N: 16040067
|
🔒 Subscribe | |
|
|
SCILOG | SCIPRO L/P |
SCILOG SCIPRO L/P PERISTALTIC PUMP, INCLUDES SCILOG SCIPRO DIGITAL CONTROL DOLLY SK: 01 56C S/N: 800139611100 RATIO: 7.8 S.F. MAX TORQ: 350 IN/LB VOLTS: 90 AMPS: 4.8 HP: 1/2 RPM: 225 EST. DIMS.: 32" X 15" X 21"
|
🔒 Subscribe | |
|
|
TRIVAC | D4A |
TRIVAC D4A VACUUM PUMP. THE D4A VACUUM PUMP IS A DUAL-STAGE ROTARY VANE MECHANICAL VACUUM PUMP WITH A 1/3 HP MOTOR. IT IS RELIABLE AND OPERATES QUIETLY. IT HAS EXCELLENT VAPOR HANDLING CAPABILITIES AND CAN BE USED IN MANY APPLICATIONS. S/N: 128-752-5031
|
🔒 Subscribe | |
|
|
TRIVAC | D2A |
TRIVAC D2A VACUUM PUMP. THE D2A VACUUM PUMP IS A DUAL-STAGE ROTARY VANE MECHANICAL VACUUM PUMP WITH A 1/3 HP MOTOR. IT IS RELIABLE AND OPERATES QUIETLY. IT HAS EXCELLENT VAPOR HANDLING CAPABILITIES AND CAN BE USED IN MANY APPLICATIONS. S/N: 128-426-0831
|
🔒 Subscribe |
2015 ANTARES VISION AVB 106
PHARMACEUTICAL MANUFACTURING EQUIPMENT
2015 ANTARES VISION AVB 106 AUTOMATIC TABLET VISUAL INSPECTION MACHINES FOR TABLETS & CAPSULES S/N: ...
Hammer Price:
🔒
WATERS 2695
TEST, MEASUREMENT & QUALITY EQUIPMENT
WATERS 2695 SEPARATION MODULE (WATER HPLC) DESCRIPTION: THE WATERS ALLIANCE 2695 HPLC SEPARATIONS MO...
Hammer Price:
🔒
VARIAN BIO-DIS III
PHARMACEUTICAL MANUFACTURING EQUIPMENT
VARIAN BIO-DIS III DISSOLUTION SYSTEM IS IDEAL FOR AUTOMATIC DISSOLUTION PROFILING OF EXTENDED RELEA...
Hammer Price:
🔒
KEY INTERNATIONAL TD
PHARMACEUTICAL MANUFACTURING EQUIPMENT
KEY INTERNATIONAL TD TABLET DE-DUSTER S/N: 0109602 DESCRIPTION: DESIGNED FOR THE OPERATOR IN MIND, T...
Hammer Price:
🔒
KEY INTERNATIONAL TD
PHARMACEUTICAL MANUFACTURING EQUIPMENT
KEY INTERNATIONAL TABLET DEDUSTER MODEL: TD S/N: 010487 DESCRIPTION: DESIGNED FOR THE OPERATOR IN MI...
Hammer Price:
🔒
WATERS 2695 SEPARATIONS MODULE
TEST, MEASUREMENT & QUALITY EQUIPMENT
WATERS 2695 SEPARATIONS MODULE PRODUCT NUMBER: WAT270008 SERIAL NUMBER: G07SM4515A VOLTS: 100240 AMP...
Hammer Price:
🔒
2014 METTLER TOLEDO SAFELINE METAL CHECK
PACKAGING EQUIPMENT
2014 METTLER TOLEDO SAFELINE METAL CHECK METAL CHECK SERIAL NUMBER: 522581 VOLTAGE: 100-240 FREQUENC...
Hammer Price:
🔒
WATERS 2695 SEPARATIONS MODULE, 2489 UV/VISIBLE DETECTOR
TEST, MEASUREMENT & QUALITY EQUIPMENT
WATERS 2695 SEPARATIONS MODULE PRODUCT NUMBER: WAT270886 SERIAL NUMBER: F 07SM7073A VOLTS: 100240 AM...
Hammer Price:
🔒
WATERS 2695 HPLC SEPARATIONS MODULE
TEST, MEASUREMENT & QUALITY EQUIPMENT
WATERS 2695 HPLC SEPARATIONS MODULE PRODUCT NUMBER: WAT270886 SERIAL NUMBER: F 07SM7069A VOLTS: 1002...
Hammer Price:
🔒
GEORGE NUTTING CO AV 100
PHARMACEUTICAL MANUFACTURING EQUIPMENT
GEORGE NUTTING CO AV 100 TABLET DEDUSTER S/N: 10413 ADJUSTABLE SLOPE AND VARIABLE INTENSITY VIBRATIO...
Hammer Price:
🔒
KEY INTERNATIONAL TD-101 S 03 59
PHARMACEUTICAL MANUFACTURING EQUIPMENT
KEY INTERNATIONAL TD-101 S 03 59 TABLET DEDUSTER: DESIGNED FOR THE OPERATOR IN MIND, THESE DEDUSTER ...
Hammer Price:
🔒
2019 METTLER TOLEDO SAFELINE
PHARMACEUTICAL MANUFACTURING EQUIPMENT
2019 METTLER TOLEDO SAFELINE METAL CHECK VOLTAGE: 110 AMPERAGE: 4A PHASE: 1 FREQUENCY: 50/60 S/N: B9...
Hammer Price:
🔒
2005 INCAP DOTT BONAPACE & C. IN-CAP
PHARMACEUTICAL MANUFACTURING EQUIPMENT
2005 INCAP DOTT BONAPACE & C. IN-CAP CAPSULE FILLING MACHINE S/N: 256/05 VOLT: 110 HZ: 60 BAR: 6 DES...
Hammer Price:
🔒
WATERS 2695 HPLC
TEST, MEASUREMENT & QUALITY EQUIPMENT
WATERS 2695 HPLC SEPARATIONS MODULE, FULL SPECTRUM WATER SEPARATION MODULE 2695 HPLC S/N: G07SM4552A...
Hammer Price:
🔒
AGILENT TECHNOLOGIES 708 DS
CHEMICAL PROCESSING EQUIPMENT
AGILENT TECHNOLOGIES 708 DS DISSOLUTION APPARATUS WITH PERISTALTIC PUMP MODEL NUMBER: 708 DS PRODUCT...
Hammer Price:
🔒
AGILENT TECHNOLOGIES 708DS
CHEMICAL PROCESSING EQUIPMENT
AGILENT TECHNOLOGIES 708DS DISSOLUTION APPARATUS WITH PERISTALTIC PUMP. MODEL NUMBER: 708DS PRODUCT ...
Hammer Price:
🔒
2019 AGILENT CARY 60 UV-VISION
TEST, MEASUREMENT & QUALITY EQUIPMENT
2019 AGILENT CARY 60 UV-VISION CARY 60 UV-VIS SYSTEM VERSATILITY MAKES IT IDEAL FOR MANY APPLICATION...
Hammer Price:
🔒
VARIAN VK7000
CHEMICAL PROCESSING EQUIPMENT
VARIAN VK7000 DISSOLUTION APPARATUS, S/N: 1-0951-1107. VOLTAGE: 115; FREQUENCY: 60HZ; AMPERAGE: 3. D...
Hammer Price:
🔒
AGILENT TECHNOLOGIES G7910 G7911A
CHEMICAL PROCESSING EQUIPMENT
AGILENT TECHNOLOGIES G7910 G7911A DISSOLUTION APPARATUS S/N: DL1103C309 VOLTS: 115 /230 FREQUENCY: 6...
Hammer Price:
🔒
2014 METTLER TOLEDO SAFELINE METAL CHECK
PHARMACEUTICAL MANUFACTURING EQUIPMENT
2014 METTLER TOLEDO SAFELINE METAL CHECK SERIAL NUMBER: C114493105 MODEL TO AL VOLTAGE: 100240 AMPER...
Hammer Price:
🔒
AGILENT TECHNOLOGIES G7910 G7911A
CHEMICAL PROCESSING EQUIPMENT
AGILENT TECHNOLOGIES G7910 G7911A 708-DS DISSOLUTION APPARATUS S/N: DL1103C306. PRODUCT NUMBER: G7 9...
Hammer Price:
🔒
BUDZAR LTW 22.5 SP
REFRIGERATION EQUIPMENT
BUDZAR LTW 22.5 SP PROCESS CHILLER VOLTS: 160 PHASE: 3 FREQUENCY: 60 HZ FULL LOAD AMPERAGE: 36.97 MA...
Hammer Price:
🔒
LOGAN INSTRUMENTS CORP 100 HTP
MISC
LOGAN INSTRUMENTS CORP 100 HTP AUTOMATIC VESSEL CLEANER. 12/14 VOLTS; 110 AMPERAGE; 10 HZ; 60. S/N: ...
Hammer Price:
🔒
WATERS 2695 HPLC
TEST, MEASUREMENT & QUALITY EQUIPMENT
WATERS 2695 HPLC SEPARATIONS MODULE S/N: G07SM4539A INPUT: 100-240V AMPS: 9.5 FREQUENCY: 47-63HZ DES...
Hammer Price:
🔒
WATERS 2695 HPLC
TEST, MEASUREMENT & QUALITY EQUIPMENT
WATERS 2695 HPLC SEPARATIONS MODULE. INPUT: 100-240V AMPS: 9.5 FREQUENCY: 47-63HZ DESCRIPTION: THE W...
Hammer Price:
🔒
AGILENT TECHNOLOGIES 7697A
MEDICAL & BIOTECH EQUIPMENT
AGILENT TECHNOLOGIES 7697A HEADSPACE SAMPLER 12-VIAL CAPACITY CONFIGURATION IS PERFECT FOR ACADEMIC...
Hammer Price:
🔒
1998 BOSCH KKE1500
PHARMACEUTICAL MANUFACTURING EQUIPMENT
1998 BOSCH KKE1500 TABLET INSPECTION SYSTEM S/N: 782622 VOLTAGE: 250 AMPERAGE: 30 TOOLING SETS INCLU...
Hammer Price:
🔒
2012 RIVA MINI PRESS MII
PHARMACEUTICAL MANUFACTURING EQUIPMENT
2012 RIVA MINI PRESS MII TABLET PRESS VOLTAGE: 220V PHASE: 1 THIS ECCENTRIC TABLE SINGLE-PUNCH TABLE...
Hammer Price:
🔒
LABCONCO 3946631
MEDICAL & BIOTECH EQUIPMENT
LABCONCO 3946631 FUME HOOD VOLTAGE: 115 PHASE: 1 FREQUENCY: 60 HZ AMPS: 3 DESCRIPTION: XPERT FILTER...
Hammer Price:
🔒
VARIAN VK 7000
CHEMICAL PROCESSING EQUIPMENT
VARIAN VK 7000 DISSOLUTION APPARATUS S/N: 1-0946-1107 VOLTAGE: 115V AMPS: 3 DESCRIPTION: THE VARIAN ...
Hammer Price:
🔒
SARTORIUS CAISL3-U
MISC
FLOOR SCALE PLATFORM SARTORIUS CAISL3-U FLOOR SCALE PLATFORM WITHOUT INDICATORS. DESCRIPTION: USED ...
Hammer Price:
🔒
SARTORIUS CAISL3-U
MISC
SARTORIUS CAISL3-U FLOOR SCALE PLATFORM USED TO WEIGH BULKY ITEMS SUCH AS CONTAINERS OR PALLETS, OR ...
Hammer Price:
🔒
ISOTEMP
REFRIGERATION EQUIPMENT
ISOTEMP LABORATORY REFRIGERATOR CATALOGUE NUMBER: 139 862 45GR VOLTS: 115 HERTZ: 60 AMPS: 10.5. S/N:...
Hammer Price:
🔒
2000 FELDMEIER 600 L
TANKS, PUMPS & STORAGE EQUIPMENT
2000 FELDMEIER 600 L JACKETED TANK S/N: 18S 0731 DESCRIPTION: OUTERSHELL 316 L STAINLESS STEEL NATIO...
Hammer Price:
🔒
FISHER SCIENTIFIC 725G
MISC
FISHER SCIENTIFIC 725G TEMP OVEN VOLTS: 120 AMPS: 11 FREQUENCY: 60 HZ DESCRIPTION: CONSISTENT, RELIA...
Hammer Price:
🔒
FAN TECH 150LGR
MISC
FAN TECH 150LGR DEHUMIDIFIER: LOW GRAIN REFRIGERANT SYSTEM REMOVES MORE MOISTURE FROM THE AIR THAN S...
Hammer Price:
🔒
THERMO SCIENTIFIC 2866
MEDICAL & BIOTECH EQUIPMENT
THERMO SCIENTIFIC 2866 WATER BATH. MICROPROCESSOR CONTROL WITH DIGITAL LED DISPLAY. SET TEMPERATURE ...
Hammer Price:
🔒
VWR SCIENTIFIC 750T
MEDICAL & BIOTECH EQUIPMENT
VWR SCIENTIFIC AQUA SONIC WATER BATH MODEL: 750T ULTRASONIC BATHS CREATE ULTRASONIC WAVES IN THE TAN...
Hammer Price:
🔒
THERMO SCIENTIFIC POLY 15 CIMAREC I MULTIPOINT
MISC
LOT OF 9 THERMO SCIENTIFIC POLY 15 CIMAREC I MULTIPOINT (MULTI-POSITION STIRRER) DESCRIPTION: RUGGED...
Hammer Price:
🔒
THERMO SCIENTIFIC 2849
TEST, MEASUREMENT & QUALITY EQUIPMENT
THERMO SCIENTIFIC 2849 WATERBATH S/N: 230585541 FREQUENCY: 60 HZ PHASE: 1 DESCRIPTION: THIS NON-HAZA...
Hammer Price:
🔒
MISC
BENCHTOP SOLDERING-FUME EXTRACTOR HAVE TWO ARTICULATING ARMS TO REMOVE FUMES FROM TWO WORKSTATIONS. ...
Hammer Price:
🔒
VWR 1400E
MISC
VWR 1400E OVEN VOLTS: 115 FREQUENCY: 60 HZ AMPS: 4 DIGITAL MANUAL: DESCRIPTION: THIS UNIT IS AN ECON...
Hammer Price:
🔒
PANASONIC MCO-170M
MEDICAL & BIOTECH EQUIPMENT
PANASONIC MCO-170M INCUBATOR EXTERNAL DIMENSIONS (W X D X H) 620 X 730 X 905 MM INTERNAL DIMENSIONS ...
Hammer Price:
🔒
SCILOG SCIPRO L/P
TANKS, PUMPS & STORAGE EQUIPMENT
SCILOG SCIPRO L/P PERISTALTIC PUMP, INCLUDES SCILOG SCIPRO DIGITAL CONTROL DOLLY SK: 01 56C S/N: 800...
Hammer Price:
🔒
TRIVAC D4A
MISC
TRIVAC D4A VACUUM PUMP. THE D4A VACUUM PUMP IS A DUAL-STAGE ROTARY VANE MECHANICAL VACUUM PUMP WITH ...
Hammer Price:
🔒
TRIVAC D2A
MISC
TRIVAC D2A VACUUM PUMP. THE D2A VACUUM PUMP IS A DUAL-STAGE ROTARY VANE MECHANICAL VACUUM PUMP WITH ...
Hammer Price:
🔒